Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Acta Cardiol ; 79(2): 206-214, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38465606

RESUMEN

BACKGROUND: Lipid-rich plaque covered by a thin fibrous cap (FC) has been identified as a frequent morphological substrate for the development of acute coronary syndrome. Optical coherence tomography (OCT) permits the identification and measurement of the FC. Near-infrared spectroscopy (NIRS) has been approved for detection of coronary lipids. AIMS: We aimed to assess the ability of detailed OCT analysis to identify coronary lipids, using NIRS as the reference method. METHODS: In total, 40 patients with acute coronary syndrome underwent imaging of a non-culprit lesion by both NIRS and OCT. For each segment, the NIRS-derived 4 mm segment with maximal lipid core burden index (maxLCBI4mm) was assessed. OCT analysis was performed using a semi-automated method including measurement of the fibrous cap thickness (FCT) of all detected fibroatheromas. Subsequent quantitative volumetric evaluation furnished FCT, FC surface area (FC SA), lipid arc, and FC (fibrous cap) volume data. OCT features of lipid plaques were compared with maxLCBI4mm. Predictors of maxLCBI4mm >400 was assessed by using univariable and multivariable analysis. RESULTS: OCT features (mean FCT, total FC SA, FC volume, maximal, mean, and total lipid arcs) strongly correlated with the maxLCBI4mm (p = 0.012 for the mean FCT, respectively p < 0.001 for all other aforementioned features). The strongest predictors of maxLCBI4mm >400 were the maximal (p = 0.002) and mean (p = 0.002) lipid arc, and total FC SA (p = 0.012). CONCLUSIONS: We found a strong correlation between the OCT-derived features and NIRS findings. Detailed OCT analysis may be reliably used for detection of the presence of coronary lipids.


Asunto(s)
Síndrome Coronario Agudo , Enfermedad de la Arteria Coronaria , Placa Aterosclerótica , Humanos , Placa Aterosclerótica/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico , Tomografía de Coherencia Óptica/métodos , Espectroscopía Infrarroja Corta/métodos , Síndrome Coronario Agudo/diagnóstico por imagen , Lípidos , Ultrasonografía Intervencional/métodos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología
2.
J Robot Surg ; 7(2): 103-11, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23704857

RESUMEN

CardioARM, a highly flexible "snakelike" medical robotic system (Medrobotics, Raynham, MA), has been developed to allow physicians to view, access, and perform complex procedures intrapericardially on the beating heart through a single-access port. Transthoracic epicardial catheter mapping and ablation has emerged as a strategy to treat arrhythmias, particularly ventricular arrhythmias, originating from the epicardial surface. The aim of our investigation was to determine whether the CardioARM could be used to diagnose and treat ventricular tachycardia (VT) of epicardial origin. Animal and clinical studies of the CardioARM flexible robot were performed in hybrid surgical-electrophysiology settings. In a porcine model study, single-port pericardial access, navigation, mapping, and ablation were performed in nine animals. The device was then used in a small, single-center feasibility clinical study. Three patients, all with drug-refractory VT and multiple failed endocardial ablation attempts, underwent epicardial mapping with the flexible robot. In all nine animals, navigation, mapping, and ablation were successful without hemodynamic compromise. In the human study, all three patients demonstrated a favorable safety profile, with no major adverse events through a 30-day follow-up. Two cases achieved technical success, in which an electroanatomic map of the epicardial ventricle surface was created; in the third case, blood obscured visualization. These results, although based on a limited number of experimental animals and patients, show promise and suggest that further clinical investigation on the use of the flexible robot in patients requiring epicardial mapping of VT is warranted.

3.
J Transl Med ; 11: 124, 2013 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-23688243

RESUMEN

BACKGROUND: Mild therapeutic hypothermia (HT) has been implemented in the management of post cardiac arrest (CA) syndrome after the publication of clinical trials comparing HT with common practice (ie, usually hyperthermia). Current evidence on the comparison between therapeutic HT and controlled normothermia (NT) in CA survivors, however, remains insufficient. METHODS: Eight female swine (sus scrofa domestica; body weight 45 kg) were randomly assigned to receive either mild therapeutic HT or controlled NT, with four animals per group. Veno-arterial extracorporeal membrane oxygenation (ECMO) was established and at minimal ECMO flow (0.5 L/min) ventricular fibrillation was induced by rapid ventricular pacing. After 20 min of CA, circulation was restored by increasing the ECMO flow to 4.5 L/min; 90 min of reperfusion followed. Target core temperatures (HT: 33°C; NT: 36.8°C) were maintained using the heat exchanger on the oxygenator. Invasive blood pressure was measured in the aortic arch, and cerebral oxygenation was assessed using near-infrared spectroscopy. After 60 min of reperfusion, up to three defibrillation attempts were performed. After 90 min of reperfusion, blood samples were drawn for the measurement of troponin I (TnI), myoglobin (MGB), creatine-phosphokinase (CPK), alanin-aminotransferase (ALT), neuron-specific enolase (NSE) and cystatin C (CysC) levels. Reactive oxygen metabolite (ROM) levels and biological antioxidant potential (BAP) were also measured. RESULTS: Significantly higher blood pressure and cerebral oxygenation values were observed in the HT group (P<0.05). Sinus rhythm was restored in all of the HT animals and in one from the NT group. The levels of TnI, MGB, CPK, ALT, and ROM were significantly lower in the HT group (P<0.05); levels of NSE, CysC, and BAP were comparable in both groups. CONCLUSIONS: Our results from animal model of cardiac arrest indicate that HT may be superior to NT for the maintenance of blood pressure, cerebral oxygenation, organ protection and oxidative stress suppression following CA.


Asunto(s)
Encéfalo/metabolismo , Paro Cardíaco/metabolismo , Hipotermia Inducida/métodos , Estrés Oxidativo , Oxígeno/metabolismo , Animales , Biomarcadores/sangre , Presión Sanguínea , Temperatura Corporal , Modelos Animales de Enfermedad , Oxigenación por Membrana Extracorpórea/métodos , Femenino , Sus scrofa
4.
Circ Arrhythm Electrophysiol ; 5(6): 1202-6, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23051839

RESUMEN

BACKGROUND: Several percutaneous circulatory support systems have been recently introduced into clinical practice for the treatment of cardiogenic shock or refractory nontolerated ventricular tachycardia, in support of high-risk catheter interventions and, occasionally, cardiopulmonary resuscitation. To date, however, a direct comparison of the available systems has not been performed. METHODS AND RESULTS: Adult female pigs (weight 50-60 kg) were used throughout the experiment. Under deep anesthesia and mechanical ventilation, 3 percutaneous circulatory support systems were compared: (1) right atrium-aorta, extracorporeal membrane oxygenation (n=4); (2) left atrium-aorta, TandemHeart system (n=4); (3) left ventricle-aorta, Impella 2.5 system (n=4), and (4) left ventricle-aorta with norepinephrine at 0.1 µg/kg per minute (n=4). Hemodynamic efficacy (mean arterial pressure) was measured at 3 specific conditions: ventricular pacing at 200 and 300 beats per minute, and ventricular fibrillation. Although no or only nonsignificant differences were found among the systems at ventricular pacing of 200 and 300 beats per minute, under ventricular fibrillation, the right atrium-aorta system was significantly the most efficacious, followed by the left atrium-aorta system and the left ventricle-aorta system (P<0.001). However, the left ventricle-aorta system with norepinephrine still maintained mean arterial pressure comparable with the left atrium-aorta system. CONCLUSIONS: Differences were seen in the hemodynamic efficacy of available percutaneous circulatory support systems, particularly under the most severe hemodynamic condition, ventricular fibrillation.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Corazón Auxiliar/clasificación , Hemodinámica/fisiología , Modelos Animales , Fibrilación Ventricular/terapia , Animales , Aorta/fisiopatología , Femenino , Atrios Cardíacos/fisiopatología , Ventrículos Cardíacos/fisiopatología , Hemodinámica/efectos de los fármacos , Norepinefrina/farmacología , Porcinos , Resultado del Tratamiento , Fibrilación Ventricular/fisiopatología
5.
Europace ; 10(5): 556-7, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18227352

RESUMEN

Lead and implantable cardioverter defibrillator (ICD) device failure is a severe problem in ICD therapy and may occur without preceding signs of deterioration. Insulation lead failure and subsequent ICD defect 7 months after ICD implantation for secondary prevention of sudden cardiac death (SCD) in a 70-year-old male was automatically detected with the Home Monitoring system. Immediate lead and device replacement was performed. This case illustrates the benefit of permanent automatic remote monitoring of implanted active devices.


Asunto(s)
Desfibriladores Implantables , Electrocardiografía/métodos , Electrodos Implantados , Análisis de Falla de Equipo/métodos , Telemedicina/métodos , Terapia Asistida por Computador/métodos , Anciano , Conductividad Eléctrica , Falla de Equipo , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...